This website uses cookies to ensure you get the best experience on our website.
Read more
Millipore Plate Compatibility Chart with EVOM Manual
September 05, 2023
Millipore Plate Compatibility Chart With EVOM™ Manual
By Andy Waldes
Explore the compatibility of Millipore plates with the EVOM™ Manual system. World Precision Instruments provides comprehensive insights, serving as a valuable resource for laboratories seeking to understand how these two key components work together. Use this guide to maximize the efficiency of your laboratory operations using Millipore plates and the EVOM™ Manual system.
The EVOM™ Manual requires an electrode for use. Choose an electrode suitable for your application.
Millicell Standing Inserts
Millipore Plate | Compatible TEER Electrode | Device Configuration | Description |
PSHT004 PSHT004R1 PSHT004R5 PSHT004S5 |
STX HTS | 96-well plate | Chemistry & Media: Polycarbonate (PC)/Isopore Pore Size: 0.4 µm Filtration Area: 0.11 cm² |
PSRP004 PSRP004R1 PSRP004R5 |
STX HTS | 96-well plate | Chemistry: Polyethylene Terephthalate (PET) Pore Size: 1.0 µm Filtration Area: 0.11 cm² |
PIHP01250 | STX4 Endohm-6 |
24-well plate | Chemistry & Media: Polycarbonate (PC)/Isopore Pore Size: 0.4 µm Filtration Area: 0.6 cm² |
PSHT010R PSHT010R1 PSHT010R5 |
STX4 | 24-well plate | Chemistry & Media: Polycarbonate (PC)/Isopore Pore Size: 0.4 µm Filtration Area: 0.7 cm² |
PICM01250 | STX4 Endohm-6 |
24-well plate | Chemistry & Media: Hydrophilic Polytetrafluoroethylene (PTFE) / Biopore Pore Size: 0.4 µm Filtration Area: 0.6 cm² |
PIHA01250 | STX4 Endohm-6 |
24-well plate | Chemistry & Media: Mixed Cellulose Esters (MCE) / MF-Millipore Pore Size: 0.45 µm Filtration Area: 0.6 cm² |
PSRP010 PSRP010R1 PSRP010R5 |
STX4 | 24-well plate | Chemistry: Polyethylene Terephthalate (PET) Pore Size: 1.0 µm Filtration Area: 0.7 cm² |
PITP01250 | STX4 Endohm-6 |
24-well plate | Chemistry & Media: Polycarbonate (PC)/Isopore Pore Size: 3.0 µm Filtration Area: 0.6 cm² |
PSST010R PSST010R1 PSST010R5 |
STX4 | 24-well plate | Chemistry & Media: Polycarbonate (PC)/Isopore Pore Size: 3.0 µm Filtration Area: 0.7 cm² |
PSMT010R PSMT010R1 PSMT010R5 |
STX4 | 24-well plate | Chemistry & Media: Polycarbonate (PC)/Isopore Pore Size: 5.0 µm Filtration Area: 0.7 cm² |
PI8P01250 | STX4 | 24-well plate | Chemistry & Media: Polycarbonate (PC)/Isopore Pore Size: 8.0 µm Filtration Area: 0.6 cm² |
PSET010 PSET010R1 PSET010R5 |
STX4 | 24-well plate | Chemistry & Media: Polycarbonate (PC)/Isopore Pore Size: 8.0 µm Filtration Area: 0.7 cm² |
PIXP01250 | STX4 Endohm-6 |
24-well plate | Chemistry & Media: Polycarbonate (PC)/Isopore Pore Size: 12.0 µm Filtration Area: 0.6 cm² |
PICM0RG50 | Endohm-24 | 6-well plate | Chemistry & Media: Hydrophilic Polytetrafluoroethylene (PTFE) / Biopore Pore Size: 0.4 µm Filtration Area: 4.2 cm² |
PIHP03050 | Endohm-24 | 6-well plate | Chemistry & Media: Polycarbonate (PC)/Isopore Pore Size: 0.4 µm Filtration Area: 4.2 cm² |
PICM03050 | Endohm-24 | 6-well plate | Chemistry & Media: Hydrophilic Polytetrafluoroethylene (PTFE) / Biopore Pore Size: 0.4 µm Filtration Area: 4.2 cm² |
PIHA03050 | Endohm-24 | 6-well plate | Chemistry & Media: Mixed Cellulose Esters (MCE) / MF-Millipore Pore Size: 0.45 µm Filtration Area: 4.2 cm² |
Millicell Hanging Inserts
Millipore Plate | Compatible TEER Electrode | Device Configuration | Description |
PTHT24H48 PCHT24H48 |
Endohm-6 | 24-well plate | Chemistry: Polyethylene Terephthalate (PET) Pore Size: 0.4 µm Filtration Area: 0.3 cm² |
PTRP24H48 PLRP24H48 |
Endohm-6 | 24-well plate | Chemistry: Polyethylene Terephthalate (PET) Pore Size: 1.0 µm Filtration Area: 0.3 cm² |
PTSP24H48 PCSP24H48 |
Endohm-6 | 24-well plate | Chemistry: Polyethylene Terephthalate (PET) Pore Size: 3.0 µm Filtration Area: 0.3 cm² |
PTMP24H48 | Endohm-6 | 24-well plate | Chemistry: Polyethylene Terephthalate (PET) Pore Size: 5.0 µm Filtration Area: 0.3 cm² |
PTEP24H48 | Endohm-6 | 24-well plate | Chemistry: Polyethylene Terephthalate (PET) Pore Size: 8.0 µm Filtration Area: 0.3 cm² |
PTHT12H48 | EndOhm-12 | 12-well plate | Chemistry: Polyethylene Terephthalate (PET) Pore Size: 0.4 µm Filtration Area: 1.1 cm² |
PTRP12H48 | EndOhm-12 | 12-well plate | Chemistry: Polyethylene Terephthalate (PET) Pore Size: 1.0 µm Filtration Area: 1.1 cm² |
PTSP12H48 | EndOhm-12 | 12-well plate | Chemistry: Polyethylene Terephthalate (PET) Pore Size: 3.0 µm Filtration Area: 1.1 cm² |
PTMP12H48 | EndOhm-12 | 12-well plate | Chemistry: Polyethylene Terephthalate (PET) Pore Size: 5.0 µm Filtration Area: 1.1 cm² |
PTEP12H48 | EndOhm-12 | 12-well plate | Chemistry: Polyethylene Terephthalate (PET) Pore Size: 8.0 µm Filtration Area: 1.1 cm² |
PTHT06H48 | EndOhm-24 | 6-well plate | Chemistry: Polyethylene Terephthalate (PET) Pore Size: 0.4 µm Filtration Area: 4.5 cm² |
PTRP06H48 | EndOhm-24 | 6-well plate | Chemistry: Polyethylene Terephthalate (PET) Pore Size: 1.0 µm Filtration Area: 4.5 cm² |
PTSP06H48 | EndOhm-24 | 6-well plate | Chemistry: Polyethylene Terephthalate (PET) Pore Size: 3.0 µm Filtration Area: 4.5 cm² |
PTMP06H48 | EndOhm-24 | 6-well plate | Chemistry: Polyethylene Terephthalate (PET) Pore Size: 5.0 µm Filtration Area: 4.5 cm² |
PTEP06H48 | EndOhm-24 | 6-well plate | Chemistry: Polyethylene Terephthalate (PET) Pore Size: 8.0 µm Filtration Area: 4.5 cm² |
EVOM™ Manual Electrodes
Cell Culture Insert/Transwell Type | Electrode | Advantages | Disadvantages |
Removable 24-well | STX4 | No need to transfer inserts. Take measurments in the plate. | |
Removable 24-well | EndOhm-6 | Most accurate mode of measurement, because of the larger electrode surface area and the concentric positioning of the electrodes. | Need to transfer inserts into the EndOhm chamber for making measurements. |
Removable 12-well | EndOhm-12 | ||
Removable 6-well | EndOhm-24 | ||
24- or 96-well High Throughput Screening (HTS) Plates | STX HTS | Fits perfectly in the measurment plate. Choose the option based on your specific plate. |
While the EVOM™ Manual operates on the same proven EVOM™ technology as EVOM2 and Millipore MilliCell ERS-2, significant hardware and software upgrades provide exceptional new functionality to improve reading reliability and workflow efficiency. Give us a call today to talk with an application specialist.
Millicell is a registered trademark of Merck KGaA, Darmstadt, Germany
Close