This website uses cookies to ensure you get the best experience on our website.
Read more
Micro Nitric Oxide Sensors
As low as
$1,122.00
Only %1 left
Prices valid in USA, Canada, and PR only.
Order code
Price range: $1,122 - $1,282
Prices valid in USA, Canada, and PR only.
The ISO-NOP007 has a tip diameter of just 7 microns and a length of 2mm. The response is linear over a wide dynamic concentration range of NO. The design is based on a single carbon fiber coated with WPI's NO-selective membrane. A detection limit of approximately 1 nM NO makes this electrode ideal for use in tissues and microvessels.
Prices valid in USA, Canada, and PR only.
7 and 30 µm sensors with exceptional performance – ideal for tissues and microvessels
Don't forget the SNAP! |
- Excellent selectivity to NO
- Rapid response time
- Highly sensitive
- For use with Apollo1000, Apollo4000, TBR4100 and TBR1025
- Requires cable 91580 (sold separate)
- Package of 3
Options
Order code | Length | Tip Diameter | Shape |
ISO-NOP007 | 2 mm | 7 µm | Straight |
ISO-NOPF3005 | 0.5 mm | 30 µm | Straight |
ISO-NOPF3020 | 2 mm | 30 µm | Straight |
Benefits
- Linear response over a large dynamic concentration range of NO
- Dry electrodes require no sleeves or filling solution
Applications
- NO measurement in microvessels
The ISO-NOP007 has a tip diameter of just 7 microns and a length of 2mm. The response is linear over a wide dynamic concentration range of NO. The design is based on a single carbon fiber coated with WPI's NO-selective membrane. A detection limit of approximately 1 nM NO makes this electrode ideal for use in tissues and microvessels.
The ISO-NOP30 has a tip diameter of 30 microns and is available in two different tip lengths ISO-NOP3020 has tip length of 2 mm, ISO-NO3005 has tip length of 0.5 mm). The response is linear over a wide dynamic concentration range of NO. The design is based on a single carbon fiber coated with WPI's NO-selective membrane. A detection limit of approximately 1 nM NO makes these electrodes ideal for use in tissues and microvessels.
The response of a 7μm NO sensor (ISO-NOP007) to successive additions of NO (100nM). Inset shows the linearity of the resulting calibration plot.
Simultaneous measurement of force (top trace) and changes of NO concentration (lower trace) in (A) the rat superior mesenteric artery relaxed with ACh and (B) a small human artery relaxed with ACh and SNAP. In this artery oxyhaemoglobin (oxyHb) partly reversed the increase in NO concentration with only a small change in force. [U. Simonsen, et al., J. Physiol., 1999, 516: 271-282.]
SKU | VAR-2968 |
---|
Upsell Products
-
SNAP Calibration Compound for NO Microsensors
As low as $125.00
 | ISO-NOP007 | ISO-NOP3005 | ISO-NOP3020 |
Outside Diameter |  7 µm | 30 μm | 30 µm |
Available Length | 2 mm | 0.5 mm | 2 mm |
Response Time | < 3 seconds | < 3 seconds | < 3 seconds |
Lowest Detection Limit/Range | 0.5 nMÂ | 1 nM | 1 nM |
Nominal Sensitivity-New sensor | ≥1 pA/nM | ≥1.4 pA/nM | ≥1.5 pA/nM |
Baseline Drift | none | none |  none |
Poise Voltage | 865 mVÂ | 865 mV | 865 mVÂ |
Typical Quiescent Baseline Current, 25°C | 300 pA | 1000 pA | 500 pA |
Acceptable Baseline Range | 200-1500 pAÂ | 150-3500 pA | 500-5000 pAÂ |
Polarization Time | 1+ hours | 1+ hours | 1+ hours |
Dantas, B. P. V, Ribeiro, T. P., Assis, V. L., Furtado, F. F., Assis, K. S., Alves, J. S., … Braga, V. A. (2014). Vasorelaxation induced by a new naphthoquinone-oxime is mediated by NO-sGC-cGMP pathway. Molecules (Basel, Switzerland), 19(7), 9773–9785. https://doi.org/10.3390/molecules19079773 Â