Hydrogen Peroxide Microsensors

Item#: Make Selection

ISO-HPO-100, ISO-HPO-100H

Direct quantitative measurements of hydrogen peroxide in biological samples

  • Incorporated reference electrode
  • Non-breakable integrated hydrogen peroxide sensor with tip dimension of 100 µm
  • For use with Apollo1000, Apollo4000, TBR4100 and TBR1025
  • Requires cable 91580 (sold separate)
  • Package of 3
  • See Details for part numbers and descriptions

Unit Price: varies

Qty:

Type:

For pricing, Customers outside of the US and Canada, please Contact your distributor

Options

Part # Length Tip Diameter Configuration
ISO-HPO-100 1-5 mm 100 µm Straight
ISO-HPO-100H   100 µm  Hypodermic sheath

 

See the latest Biosensor Data Sheet.

See the full-size video.

Benefits

  • Response Time: < 5 s (90%)
  • Detection Limit: 1 nM - 1 mM
  • Drift: < 1.0 pA/min. (< 2 pA/min. for the L-Shaped)
  • Sensitivity: 1 pA/nM 

Applications

  • Tissue/Microvessels detection of HPO
  • L-Shaped for tissue bath studies
  • Hypodermic for easy insertion into tissue

Despite the recognized importance of this oxidant in biology, real-time measurements at low concentration have been difficult. The hydrogen peroxide sensors developed by WPI are designed to compliment existing high sensitivity fluorescent approaches with direct quantitative measurement in biological samples in the low nM range.

The ISO-HPO-2 is a 2.0 mm stainless steel sensor, with replaceable membrane sleeves (600012) and an internal refillable electrolyte (100042). It is designed for use in cell cultures and similar applications.

The ISO-HPO-100 is a 100 µm tip diameter hydrogen peroxide micro sensor designed for use in tissues and similar applications. The design is based on a platinum wire sensing electrode coated with a proprietary membrane to enhanceH2Odetection.

These sensors incorporate WPI’s proprietary combination electrode technology whereby the hydrogen peroxide sensing element and separate reference electrode are encased within a single Faraday-shielded probe design. This design has been shown to enhance performance during measurements and minimizes overall sensor size.

Our hydrogen peroxide (H2O2) sensors work with the TBR4100 and TBR1025 free radical analyzers.

Hydrogen peroxide in biological systems

Hydrogen Peroxide is produced in biological systems by controlled pathways at low concentrations that impact on cell signaling. At higher concentrations inflammatory cells produce local intense amounts of this oxidant to kill pathogens. In the progress of human disease, uncontrolled formation of hydrogen peroxide from the mitochondrial respiratory chain and enzymes, such as xanthine oxidase, can occur (Prof. Victor Darley-Usmar, Univ. of Alabama, personal communication). 

Hydrogen peroxide sensor in a hypodermic sheath

The ISO-HPO-100H is enclosed in a hypodermic needle. The image below shows the needle tip and enclosed sensor as viewed through a microscope.

Needle tip 

L-shaped hydrogen peroxide sensor

The ISO-HPO-100-L is a unique L-shaped nitric oxide sensor designed specifically for use in tissue bath studies and similar applications (e.g., see WPI's MYOBATH). The shape of the sensor has been engineered to facilitate placement of the electrode within the lumen of the tissue vessel under study.

L-shaped ISO-HPO-100L

 

 

ISO-HPO-100

ISO-HPO-100 H

APPLICATION Tissue/Microvessels Hypodermic Sheath
SENSOR DIAMETER 100 µm 100 µm
RESPONSE TIME < 5 SEC (90%) < 5 SEC (90%)
DETECTION LIMIT 1 nM to 1 mM < 10 nM to 1 mM
DRIFT < 2.0 pA/min < 2.0 pA/min
SENSITIVITY 1 pA/nM 1 pA/nM
PHYSIOLOGICAL INTERFERENCE Contact WPI Contact WPI