  • Replacement tips for KWIK-TIP Ion Selective Electrodes

Replacement tips

Set of 3 calcium replacement tips for ion selective electrodes. Change the tip on your holder in less than a minute.

Notes

The tips should be stored dry under refrigeration prior to use. Once filled, the membrane tip can last up to 30 days and be used for that length of time. The tip is fragile and the “membrane” gets softer when wetted. After use, the tips can be placed into storage. Before storage, wash the exterior and carefully blot it dry. Leave the filling solution inside the electrode and seal it with parafilm. Then, place it in a dry container and store it in the refrigerator.

The KWIK Ag/AgCl pellet should be washed in distilled water, dried and stored in a dry, dark location. If desired, you may change to a new ionic solution, however, it takes time for the old ionic solution to exchange out of the KWIK pellet and be replaced with the new ionic concentration.This should be done in a small beaker and the contaminated solution should be discarded.  The new tip and electrode should be filled with fresh solution.

  Electrode
Color Code
Filling Solution
Nim. Slope/Decade
Concentration Range
Selectivity Coeffiecients (-log)
TIPCA
Calcium Green 0.1M CaCl2 28mV 0.1 - 10-6.75M Na+ 5.5, K+ 5.4, Mg++ 4.9
TIPH
Hydrogen Orange 1M Citric acid, 0.01M NaCl, pH 5.6 54mV pH 5.0-12 Na+ 10.4, K+ 9.8, Ca++ 11.1
TIPK
Potassium Yellow 0.1M KCl 54mV 0.1 - 10-4.5M Na+ 4.0, Ca++ 3.9, Mg++3.0
TIPTPP
TPP+ Purple 10mM TPP+ 54mV 0.001 - 10-4M K+ 6.0
More Choices:
  1. Dri-Ref Reference Electrode, 4.7 mm
    Dri-Ref Reference Electrode, 4.7 mm
    DRIREF-5
    $130.00
  2. Dri-Ref Reference Electrode, 4.7 mm (short)
    Dri-Ref Reference Electrode, 4.7 mm (short)
    DRIREF-5SH
    $130.00
  3. Dri-Ref Reference Electrode with Luer Tip
    Dri-Ref Reference Electrode with Luer Tip
    DRIREF-L
    $217.00
  4. Flexible Dri-Ref Reference Electrode
    Flexible Dri-Ref Reference Electrode
    FLEXREF
    $130.00
  5. Electrode Holder for KWIK-Tips
    Electrode Holder for KWIK-Tips
    KWIK-2
    $164.00
  6. Micro Dri-Ref Reference Electrode
    Micro Dri-Ref Reference Electrode
    DRIREF-450
    $217.00
  7. Dri-Ref Reference Electrode, 2 mm
    Dri-Ref Reference Electrode, 2 mm
    DRIREF-2
    $130.00
  8. Dri-Ref Reference Electrode, Short
    Dri-Ref Reference Electrode, Short
    DRIREF-2SH
    $130.00
  9. Hydrogen Electrode Tip, Replacement
    Hydrogen Electrode Tip, Replacement
    TIPH
    $243.00
  10. Super Dri-Ref Reference Electrode
    Super Dri-Ref Reference Electrode
    SDR2
    $176.00
  11. TPP Electrode Tips, Replacement
    TPP Electrode Tips, Replacement
    TIPTPP
    $179.00
Frequently Purchased
©Copyright 2020. World Precision Instruments. All rights reserved.

Apply for Tax Exempt Status
WPI collects tax in AL, AZ, CA, CO, CT, DC, FL, GA, IL, IN, MA, ME, MD, MI, MN, MO, NC, NV, NJ, NY, OH, OK, PA, SC, TN, TX, VA, VT, WA and WI