EVOM™ AutoLCI : EVOM™ Automated Live Cell Imaging system

As low as $22,220.00
Only %1 left
Prices valid in USA, Canada, and PR only.
Order code
Price range: $22,220 - $29,500
Prices valid in USA, Canada, and PR only.

EVOM™ AutoLCI is an automated live cell imaging system that is equipped with an advanced fluorescence and bright field microscopy, auto-focusing and real-time, multi-position imaging technology for a well plate, dish or T-flask. The streamlined process provides an easy workflow solution giving you a full set of tools you need to acquire the best quality images and accurate research results. The compact nature of the EVOM™ AutoLCI allows positioning in an incubator, providing improved cell viability, because there are fewer disturbances over the course of your experiment, reducing chances of cellular abnormality.

Prices valid in USA, Canada, and PR only.

Simplify your Image Capture with EVOMTM Automated Live Cell Imaging System

Live cell imaging 360

 

 

 

 

 

 

 

 

 

Options

 Order code Description
EVI-LCI-01-01 EVOM™ AutoLCI, Brightfield, 4X Magnification
EVI-LCI-01-02 EVOM™ AutoLCI, Brightfield, 10X Magnification
EVI-LCI-01-03 EVOM™ AutoLCI, Brightfield, 4X Magnification, with Green Fluorescence
EVI-LCI-01-04 EVOM™ AutoLCI, Brightfield, 10X Magnification, with Green Fluorescence
EVI-LCI-01-05 EVOM™ AutoLCI, Brightfield, 4X Magnification, with Red Fluorescence
EVI-LCI-01-06 EVOM™ AutoLCI, Brightfield, 10X Magnification, with Red Fluorescence

 

The EVOM™ AutoLCI live cell imaging system includes two software packages:

  • EVOM™ AutoLCI Scan to control the actual operation of EVOM™ AutoLCI device which includes real-time cell monitoring and time-lapse imaging functions.
  • EVOM™ AutoLCI Analysis for analyzing and post-processing of the images. This comes with an unlimited software usage license, ideal for allowing multiple users to work with the unit without additional fees.

 

Expand Your Cell Discoveries with EVOM™ Automated Live Cell Imaging

Benefits of automated live cell imaging

 

 

multi-position


Multi-position imaging
- Fully-automated, multi-position imaging for high resolution analysis with a motorized camera that allows for multi-point imaging up to 96 wells.

 

Compatible vessel types
High compatibility
- Compatible with various cell and tissue culture vessel types.

 

Small footprint, compact size
Compact size
- EVOM™ AutoLCI is a live cell imaging system that easily fits into a standard CO₂ incubator.

 

Z-Stacking for HDR
Z-stacking imaging
- Capture multiple focal planes and use the Z-stacking function to view high dynamic range (HDR) images.

 

Stitching images together
Image stitching
- Stitching combines images for analysis of a single high resolution composite image. This enables analysis of a larger volume and sections.

 

auto-focusing
Auto-focusing
- You get increased focus speed and reproducibility with reliable auto-focusing function.

 

intuitive software
Intuitive interface
- With user-friendly functions, the easy-to-use analysis tools such as confluency mark, growth curve and a ruler are build into the included software.

 

Fluorescence imaging - One color fluorescence (Green or Red) and bright field imaging.

Benefits Unique to EVOM™ AutoLCI

For automated Live Cell Images you have choices. Here's what makes EVOM™ AutoLCI unique in its class:

  1. Stable Stage – Get clearer images with a stable plate. Unlike other devices, EVOM™ AutoLCI has a fixed stage and the optics move.
  2. Open-Source Data – Unlike other brands, EVOM™ AutoLCI gives you the raw images so that you can work with any analysis software you prefer, like Image J.
  3. Regular Software Updates – Stay current with all the new functions of the EVOM™ AutoLCI software. Customers are lifetime members and are never charged for the software updates.
  4. Unlimited Software Usage License – Multiple users may analyze images using their own computers (after the scanning is complete) without additional fees. Other brands limit usage to one computer.

Multi-Point Imaging

  • The camera system travels 117mm x 77mm (x and y axis respectively), multiple points within the travel range can be captured following the schedule (intervals, cycles, total time) you set.
  • Different kinds of vessels can be used (Well plates, dishes, flasks, slides)

AUTOLCI -for different vessel types

Stable Imaging Performance

  • EVOM™ AutoLCI has a stationary stage, and the camera (located inside the system) moves to capture the images of cell in multiple positions. This offers greater stability of the live cell imaging platform.
  • Precise and sensitive fluorescence detection is possible with the integrated, hard-coated, optical setup and LED filter with more than 50,000-hour lifetime.

AUTOLCI

Compact Size

  • EVOM™ AutoLCI is compact in size with 226(h) x 358(l) x 215(w)mm, which allows several EVOM™ AutoLCI systems to fit into a standard CO2 incubator.
  • Maintaining the performance of a device working in a hot and humid environment is very challenging. With EVOM™ AutoLCI, you can easily monitor live cells inside the incubator without disturbing the environment suitable for cell culture, even for extended periods.

AUTOLCI

Scanning Application

The scanning application is used for capturing images. You can preview cells, schedule image capture, adjust light and contrast, and monitor time lapse progression from one intuitive screen. It includes auto-focusing technology that finds a clear focal plane of cells and has excellent repeatability.

Z-Stacking

With the Z-stacking function, where images of multiple planes of focus are merged, spheroid cells can be clearly observed under time-lapse imaging.

Z-stacking in the software

Image Stitching

Image stitching lets you capturing multiple images and combine the overlapping parts to enable high-resolution mapping of a large sample area.

image stitching

Time Lapse Imaging

The EVOM™ AutoLCI Scan app gives you an intuitive interface for scheduling your time-lapse images. You can set the total time, cycle and intervals for the time lapse images of your live cell imaging setup.

AUTOLCI time lapse

Analysis Application

A variety of tools in the analysis application simplify the analytic process, reducing errors and saving time. 

  • Intensity Histograms
  • Confluency Graphs
  • Channel Merge
  • Video Creation
  • Manual Counting
  • Measurement
  • More

AUTOLCI analysis app software

More Information
SKU VAR-AUTOLCI
Type Description
Dimension 226 x 358 x 215 mm
Weight 5.6kg/12.3lb
Objective Lens 4X/10X
Imaging Modes Bright field, Fluorescence (Green/Red)
Fluorescence Green: Excitation (470/40x) / Emission (510lp)
Red: Excitation (510/84x) / Emission (570lp)
Light Source LED
Camera 5MP CMOS
Imaging Positions Multiple
File Export Format TIFF, AVI, JPEG, PNG
Culture Vessels Well plate (6, 12, 24, 48, 96-well), Dish (35mm, 60mm, 90mm), and T-flask (25cm2, 75cm2)
Operating Environment 10~40℃, 20~95% humidity
Power Requirements 100-240V, ~50/60Hz
Output Ports Ethernet
Computer (Recommendation)* Windows 10, 1TB Storage, 1920*1080 pixel Monitor (Full HD)
Software Included EVOM™ AutoLCI Scan and EVOM™ AutoLCI Analysis (Requires Windows 10 computer, not included)
Accessories Included PoE adapter, ethernet cable, USB/LAN adapter, USB memory
Warranty 1 year

*Computer is required for EVOM™ AutoLCI Scan and EVOM™ AutoLCI Analysis software, but is not included.
Specifications are subject to change without notice.

Back to Top