CardioPhys™ ECG

$2,500.00
Order code
VAR-CARDIOPHYS
ECG Monitoring System
  • For each heartbeat, a wave of cardiac muscle contraction pushes blood through the heart. 

  • Cardiac muscle cells are signaled in succession by an electrical signal that precedes contraction.

  • Cells depolarize in a “wave” that causes cells to contract.

  • Then the cells repolarize back to normal in succession.

  • The signature of the electrical signal as it moves through the heart is measured.

  • The ECG is the sum of all depolarization (and repolarization) events. 

  • The sum of all electrical activity in the heart is illustrated in an ECG trace.  

  • Display of the signal is a graphical representation of the signal for contraction (and relaxation). 

Options

Part # System Size
CARDIOPHYS-PRO
  • CardioPhys™ ECG unit
  • MD4 Manipulator
  • ECG-PROBE CardioPhys™ probe with low-noise, active headstage
  • CardioPhys™ ECG reference electrode assembly
  • CardioPhys™ ECG startup kit with various connectors for electrode connection and a microelectrode holder 
19in x 19in x 19in
CARDIOPHYS
  • CardioPhys™ ECG unit
  • ECG-PROBE CardioPhys™ probe with low-noise, active headstage
  • CardioPhys™ ECG reference electrode assembly
  • CardioPhys™ ECG startup kit with various connectors for electrode connection and a microelectrode holder 
17in x 13in x 6in

Benefits

  • Produces serviceable ECG signals from small and large animals
  • Easy to setup and configure
    • Detailed instructions
  • Package contains the key components
    • Amplifier, electrodes, wires
  • Exceptional quality components
    • High sensitivity
    • Low noise
  • Reliable source
    • >40 years in business measuring small signals
    • Personalized customer service (sales and technical)

Applications

  • Translational
    • Data is similar
    • Analysis tools
  • Robust analysis of heart function
    • Chamber function
    • Autonomic control mechanisms
    • Channel pathologies
  • Physiological phenotype
    • Genome-to-phenome (phenomics)
    • Toxicants, drugs, etc.
    • Stressors (environmental)
    • Detailed physiological signatures of effect
  • Expansion of lab capabilities
    • New (robust) data generation
    • Little overhead (i.e. compare to histology, molecular, etc.)

The CardioPhys™ ECG system is a highly versatile tool for measuring ECG of a wide spectra of animals – as small as a zebrafish embryo to animals as large as an alligator.

The CardioPhys™ ECG is a bioamplifier that is designed to amplify the sum of electrical potentials from cardiac muscle, and other extracellular signals. The signal produced from cardiac recordings tracks the depolarization and repolarization of the cardiomyocytes as they contract in succession to pump blood through the heart. The amplifier is powered by two 9 V batteries to minimize electrical noise, which could interfere with or mask the voltage signal from the heart.

How It Works

The CardioPhys™ ECG unit receives its input signal from a head stage connected to two electrodes. The electrodes are attached to the animal across the area where an electrical field is generated by the heart. An additional third electrode serves as a ground, which can be either attached to the animal or immersed within a conductive medium surrounding the animal. When the electrodes are attached to the animal, the ground wire serves to complete two circuits, one from each electrode to the common ground electrode. The CardioPhys™ ECG then sends the signal output to a data acquisition system as a voltage signal.

The CardioPhys™ ECG unit has high pass and low pass filters.

  • The high pass allows only frequencies above a specified value to “pass,” and eliminates any frequencies below that set value.
  • The low pass filter allows frequencies below the specified value to pass and eliminates any frequencies above that set value.

A position dial can adjust the zero, in case of signal drift. The amplification of the signal can be increased from 100X, to 1,000X to 10,000X the incoming signal.

The CardioPhys™ ECG unit includes electronics within the system (both the amplifier and the head stage) that are maximized for low noise recording of very small signals using either glass or metal microelectrodes. The CardioPhys™ ECG unit is versatile enough to measure extracellular voltage signals from animals as small as a hatched zebrafish embryo to animals as large as an alligator (or elephant) to record electrical potentials at the cell or tissue level.

The CardioPhys™ ECG is designed to amplify extracellular biopotentials. These battery powered bioamplifiers incorporate a compact chassis profile that allows the units to be located close to the preparation, which helps minimize long lead lengths that often contribute to noise. 

 

CardioPhys™ Only (CARDIOPHYS)

CardioPhys™ Only (CARDIOPHYS)

CardioPhys™ With MD4 Manipulator (CARDIOPHYS-PRO)

CardioPhys™ With MD4 Manipulator

 

INPUT IMPEDANCE 1012 Ω, common mode and differential
INPUT LEAKAGE CURRENT 50 pA (typical)
COMMON MODE REJECTION RATIO 100 dB @ 50/60 Hz
INPUT CAPACITANCE 20 pF
AC MODE NOISE 0.4 µV RMS (2uV p-p) 0.1-100 Hz
AC MODE NOISE 2.6 µV RMS (10uV p-p) 1Hz-10 kH
BANDWIDTH FILTER SETTINGS, AC Mode Low frequency, 0.1, 1, 10, 300 Hz
BANDWIDTH FILTER SETTINGS: AC Mode High frequency, 0.1, 1, 3, 10 kHz
OUTPUT CONNECTORS Audio Jack connector
OUTPUT VOLTAGE SWING ±8V
OUTPUT IMPEDANCE 470 Ω
BATTERY TEST Audible tone
CALIBRATOR SIGNAL 10 Hz square wave
POSITION Approximately 250 mV
CURRENT SOURCE:DAM80: DC Generator 0 to ±50 µA, variable
EXTERNAL COMMAND Input Voltage ±10 V commands
AC or DC current waveform ±50 µA max. amplitude @ 200 Ω
BATTERIES 2 x 9 V alkaline (included)
More Choices:
  1. ECG Probe
    ECG Probe
    ECG-PROBE
    $510.00
  2. ECG Reference Cell
    ECG Reference Cell
    300726
    $64.00
Copyright © World Precision Instruments. All rights reserved.

Apply for Tax Exempt Status
WPI collects tax in AL, AZ, CA, CO, CT, DC, FL, IL, IN, MA, ME, MD, MI, MN, MO, NC, NV, NJ, OH, OK, PA, SC, TN, VA, VT and WI