This website uses cookies to ensure you get the best experience on our website.
Read more
CardioPhys™ ECG
As low as
$3,033.00
Only %1 left
Prices valid in USA, Canada, and PR only.
Order code
Price range: $3,033 - $10,631
Prices valid in USA, Canada, and PR only.
The CardioPhys™ ECG system is a highly versatile tool for measuring ECG of a wide spectra of animals – as small as a zebrafish embryo to animals as large as an alligator.
The CardioPhys™ ECG is a bioamplifier that is designed to amplify the sum of electrical potentials from cardiac muscle, and other extracellular signals. The signal produced from cardiac recordings tracks the depolarization and repolarization of the cardiomyocytes as they contract in succession to pump blood through the heart. The amplifier is powered by two 9 V batteries to minimize electrical noise, which could interfere with or mask the voltage signal from the heart.
Prices valid in USA, Canada, and PR only.
ECG Monitoring System
Features
- For each heartbeat, a wave of cardiac muscle contraction pushes blood through the heart.
- Cardiac muscle cells are signaled in succession by an electrical signal that precedes contraction.
- Cells depolarize in a “wave” that causes cells to contract.
- Then the cells repolarize back to normal in succession.
- The signature of the electrical signal as it moves through the heart is measured.
- The ECG is the sum of all depolarization (and repolarization) events.
- The sum of all electrical activity in the heart is illustrated in an ECG trace.
- Display of the signal is a graphical representation of the signal for contraction (and relaxation).
Options
Order code | System | Size |
CARDIOPHYS-PRO |
|
19in x 19in x 19in |
CARDIOPHYS |
|
17in x 13in x 6in |
Benefits
- Produces serviceable ECG signals from small and large animals
- Easy to setup and configure
- Detailed instructions
- Package contains the key components
- Amplifier, electrodes, wires
- Exceptional quality components
- High sensitivity
- Low noise
- Reliable source
- >40 years in business measuring small signals
- Personalized customer service (sales and technical)
Applications
- Translational
- Data is similar
- Analysis tools
- Robust analysis of heart function
- Chamber function
- Autonomic control mechanisms
- Channel pathologies
- Physiological phenotype
- Genome-to-phenome (phenomics)
- Toxicants, drugs, etc.
- Stressors (environmental)
- Detailed physiological signatures of effect
- Expansion of lab capabilities
- New (robust) data generation
- Little overhead (i.e. compare to histology, molecular, etc.)
How It Works
The CardioPhys™ ECG unit receives its input signal from a head stage connected to two electrodes. The electrodes are attached to the animal across the area where an electrical field is generated by the heart. An additional third electrode serves as a ground, which can be either attached to the animal or immersed within a conductive medium surrounding the animal. When the electrodes are attached to the animal, the ground wire serves to complete two circuits, one from each electrode to the common ground electrode. The CardioPhys™ ECG then sends the signal output to a data acquisition system as a voltage signal.
The CardioPhys™ ECG unit has high pass and low pass filters.
- The high pass allows only frequencies above a specified value to “pass,” and eliminates any frequencies below that set value.
- The low pass filter allows frequencies below the specified value to pass and eliminates any frequencies above that set value.
A position dial can adjust the zero, in case of signal drift. The amplification of the signal can be increased from 100X, to 1,000X to 10,000X the incoming signal.
The CardioPhys™ ECG unit includes electronics within the system (both the amplifier and the head stage) that are maximized for low noise recording of very small signals using either glass or metal microelectrodes. The CardioPhys™ ECG unit is versatile enough to measure extracellular voltage signals from animals as small as a hatched zebrafish embryo to animals as large as an alligator (or elephant) to record electrical potentials at the cell or tissue level.
The CardioPhys™ ECG is designed to amplify extracellular biopotentials. These battery powered bioamplifiers incorporate a compact chassis profile that allows the units to be located close to the preparation, which helps minimize long lead lengths that often contribute to noise.
CardioPhys™ Only (CARDIOPHYS)
CardioPhys™ With MD4 Manipulator (CARDIOPHYS-PRO)
SKU | VAR-CARDIOPHYS |
---|
Upsell Products
- $620.00
FAQ
Does the CARDIOPHYS include an output cable?
The CARDIOPHYS system does not include and output cable like the CBL102 (BNC- 3.5 mm MiniPhone plug) because the data acquisition system can vary according to what the customer may already have. If the customer already has a data acquisition system then we can offer a cable to connect the CARDIOPHYS to their system, if one is available. The output connection on the CARDIOPHYS is a 3.5 mm MiniPhone plug. If the customer does not have a data acquisition system then we offer along with the CARDIOPHYS a LAB-TRAX-4, 505195 (ECG Analysis Module), 2851, and CBL102 cable.
We only offer two cables with 3.5 mm MiniPhone plug:
INPUT IMPEDANCE | >1012 Ω, common mode and differential |
INPUT LEAKAGE CURRENT | 50 pA (typical) |
COMMON MODE REJECTION RATIO | 100 dB @ 50/60 Hz |
INPUT CAPACITANCE | 20 pF |
AC MODE NOISE | 0.4 µV RMS (2uV p-p) 0.1-100 Hz |
AC MODE NOISE | 2.6 µV RMS (10uV p-p) 1Hz-10 kH |
BANDWIDTH FILTER SETTINGS, AC Mode | Low frequency, 0.1, 1, 10, 300 Hz |
BANDWIDTH FILTER SETTINGS: AC Mode | High frequency, 0.1, 1, 3, 10 kHz |
OUTPUT CONNECTORS | Audio Jack connector |
OUTPUT VOLTAGE SWING | ±8V |
OUTPUT IMPEDANCE | 470 Ω |
BATTERY TEST | Audible tone |
CALIBRATOR SIGNAL | 10 Hz square wave |
POSITION | Approximately 250 mV | BATTERIES | 2 x 9 V alkaline (included) |