This website uses cookies to ensure you get the best experience on our website.
Read more
Pneumatic PicoPump with vacuum
$3,936.00
Prices valid in USA, Canada, and PR only.
Order code
SYS-PV830
Prices valid in USA, Canada, and PR only.
Although syringe and piston techniques are popular for microinjection in the nanoliter range, microinjection of sub-nanoliter volumes through a very small opening in a glass micropipette is often better accomplished with a controlled burst of gas pressure. Designed to simplify intracellular injection and a variety of other microinjection tasks, WPI’s PicoPumps use precisely regulated pressures for securing cells and injecting them with fluid. Injected volumes range from picoliters to nanoliters. Separate ports supply positive and negative pressure—positive pressure for high-pressure ejection, and suction for supporting the cell or for filling the pipette from the tip. In the time between injections, a secondary default “hold” pressure is applied to the pipette to prevent fluid uptake through capillary action or diffusion. The pressure pulses are typically controlled by a precision timer. Timing, ejection pressure, holding pressure and suction are adjusted independently by control knobs and monitored with indicator gauges on the front panel. Injection pressure is controlled by a 20-turn regulator on the front panel. The built-in timing function controls the amount of time that the injection pressure is applied with millisecond resolution. Time intervals can range from 10 s down to 10 ms or less. The pressure burst can also be controlled manually or triggered by an external source.
To learn more about our warranty options, click here.
Prices valid in USA, Canada, and PR only.
Pneumatic microinjector with vacuum pressure
See the current Spec Sheet and the Microinjection Spec Sheet.
Features
- Inject into a single cell with picoliter volumes
- Regulated Hold, Ejection and Vacuum Pressure
- Carefully regulated air pressures for securing cells and injecting them with fluid
- Independent vacuum regulation
- Pressure Input: 0-120 psi
- Pressure Output: 0.3-90 psi
Benefits
- Hold pressure prevents backfilling of the pipette by capillary action
- PV830 includes vacuum pressure for filling pipettes from the tip or securing floating cells during injection
- Premium Warranty Available
Applications
- Intracellular injection in the picoliter to nanoliter range
Components
The PV830 System includes all the components listed below.
Order code | Description | Quantity |
PV830 | PicoPump | 1 |
Items listed below are already included with NANOLITER2020 System or can be purchased separately: | ||
3316 Startup Kit includes: | ||
0.25” female NPT fitting for nitrogen tank regulators | 1 | |
PV830 vacuum connector, silicone | 1 | |
5’ length of hard pressure tubing, 1/4” OD. | 1 | |
5430-ALL PicoNozzle kit includes: | ||
PicoNozzle tip assemblies (Handle diameter is 6.25 x 100mm) | 2 | |
10’ tubing | 1 | |
1.0mm pipette gaskets (green) | 4 | |
1.2mm pipette gaskets (black) | 4 | |
1.5mm pipette gaskets (red) | 4 | |
1.65mm pipette gaskets (white) | 4 |
The PV830 model provides separate regulation and pressure gauges for the eject and hold pressures. In addition to the features of the PV820, the PV830 model also includes a vacuum pressure regulator and vacuum gauge.
PicoNozzle Kit 5430-ALL (included) allows micropipettes to be securely mounted in micro-positioners for stable axial air delivery.
The optional 5430-XX PicoNozzle Kit has a Luer-fitted pipette holder for quick and easy changes. Choose your kit based on the pipette OD (XX indicates OD: 1.0, 1.2, 1.5 or 2.0 mm). The red handle has a larger diameter so that it fits easily into most manipulators. This kit contains:
(1) MPH6S microelectrode holder
(1) Handle for the MPH6S (4" hollow tube with male Luer fitting at both ends-handle diameter is 6.25 x 100 mm.)
(1) 5’ tubing (0.060" ID, 0.120" OD, male locking Luer fitting on one end and a female locking Luer fitting at the other end, rated for 200 PSI and 86 durometer shore A)
Hold Pressure Prevents Backfilling
Like the PV830, the PV820 was designed to simplify intracellular injection. The hold pressure prevents backfilling of the pipette by capillary action. Simple to use. Reliable every time.
Each PicoPump is supplied with a 5430-ALL kit that includes two PicoNozzles and tubing to connect the holders to the pressure and vacuum ports.
Vacuum Pressure for Additional Applications
Eject pressure supplies a high-pressure pulse for injecting fluid. Hold pressure, which is not sufficient to cause fluid ejection, is used to prevent back filling of the pipette by capillary action or diffusion when the solenoid is inactive. Vacuum can be applied through the ejection port, but vacuum in the PV820 must be externally regulated. To fill pipettes from the tip or through a secondary port to secure a floating cell during microinjection, vacuum may be switched from regulated vacuum to atmosphere by using the switch on the front panel.
Microinjection System
The PV820 is our popular pump for microinjection. A basic system shown below includes:
- PZMIII-MI microscope with lighted base
- PV820 PicoPump
- M3301 Micromanipulator
- 5430-ALL PicoNozzle Kit
- M10 magnetic stand
- 5052 steel base plate
Also shown in the image is the PUL-1000 micropipette puller, surgical instruments, pre-pulled MicroTips and some capillary glass.
This system is ideal for use with Zebrafish, C. Elegans, Drosophila and Xenopus. Our customizable microinjection system is also suitable for microinjection applications, including CRISPR/Cas9.
The system is completely customizable. To see some of the options, take a look at the Microinjection Toolbox article on the blog.
If you have any questions about our Microinjection Systems, please give us a call at (866) 606-1974 (Toll free in the USA) or email us at [email protected].
SKU | SYS-PV830 |
---|
Upsell Products
-
Pre-Pulled Glass Pipettes/Pack of 10
As low as $209.00 -
Pre-Pulled Glass Pipettes, Luer/Pack of 10
As low as $209.00
PV830 Manual
Syringe Volume Calculation Spreadsheet - Use this .XLS spreadsheet to calculate the volume of your syringe when you are using an UMP3, DMP, MMP or PV820/PV830.
PRESSURE | |
Pressure Input | 0-120 PSI |
Pressure Output | 0.3-90 PSI |
Pressure Burst Timer (10-turn dial) | 10 ms to 10 s in Timed mode |
Regulator Accuracy | 0.1% (20-turn dial) |
Regulator Repeatability | 0.05 PSI (both hold and eject pressures) |
Gauge Accuracy | 3% at full scale (both hold and eject pressures) |
Input Connector | Quick Connect (1/4" OD tubing) |
Output Connector | Barbed (1/16" ID tubing) |
VACUUM | |
Vacuum Input | 0-30.0" Hg |
Vacuum Output | 0.2-29.9" Hg |
Lowest Regulated Vacuum | 3" water |
Regulator Accuracy | 0.1% (20-turn dial) |
Regulator Repeatability | 0.03" Hg |
Guage Accuracy | 3% at full scale |
Input Connector | Quick Connect (1/4" OD tubing) |
Output Connector | Barbed (1/16" ID tubing) |
Control | Manual |
Vent | Atmosphere |
Fuse | |
Fuse (Older models) | 120 V: 0.5 A, fast, 0.25x1.25” USA 230 V: 0.25 A, fast, 0.25x1.25” USA |
Fuse (2019 models) | 120 V: 0.5 A, fast, 5 x 20 mm metric 230 V: 0.25 A, fast 5 x 20 mm metric |
CONNECTIONS INCLUDED | |
Input Kit | 10' nylon tubing (0.25" OD, 1000 PSI), one 1/2" female NPT adapter |
Output Kit | Two PicoNozzle |
PHYSICAL SPECS |
|
Power | 95-135 V or 220-240 V, 50/60 Hz |
Dimensions | 17 x5.25 x 9.5" (43 x 13 x 24 cm) |
Shipping Weight | 14 lb. (6.3 kg) |