Accurately measure hydrogen

These highly stable electrodes ac­cu­rate­ly measure cal­ci­um, po­tas­si­um, hydrogen and TPP (Tetraphenylphosphonium) ion activity. Tips consist of 2 mm di­am­e­ter plas­tic tubes sealed at one end with an ion-sen­si­tive mem­brane. After filling with elec­tro­lyte so­lu­tion, you can in­sert the tube into the hold­er and con­nect it to a pH meter. Tips and hold­ers are in­ter­change­able, so one tip may be re­placed with an­oth­er sensitive to a dif­fer­ent ion. Replac­ing a tip takes less than a minute. Elec­trode tips nor­mal­ly last sev­er­al months, when stored proper­ly in sa­line so­lu­tion. When re­place­ment is neces­sary, only the tip needs be re­placed.

Prices valid in USA, Canada, and PR only.

Features

  • Fast, accurate, economical
  • Superior, stable PVC membrane
  • Fast response
  • 2mm diameter tips
  • Interchangeable tip holder
  • Each kit includes 3 electrode tips and MicroFil filling syringe

Benefits

  • Inexpensive
  • Use to measure various ions in biological media

Applications

  • Detection of ions in vivo or in vitro for biological applications

 

Kwik-Tip electrodes are available separately and as kits. Each “KWIK” Elec­trode Holder kit includes a reus­able hold­er and three re­mov­able tips. In addition to a 4-foot BNC ca­ble and an electrolyte filling syringe; “TIP” Elec­trode Kits con­tain three elec­trode tips for a specific ion. A separate ref­er­ence electrode, such as WPI’s Dri-Ref™, is also required.

If your pH meter requires a US Standard connector, you will also need Part 3508 (BNC-to-US pH Standard adapter).

 

This product requires the use of a reference electrode, like the DriRef-2. For a complete list of the DriRef electrodes, refer to the Accessories tab.

 kwiktipapplication.png

More Information
SKU KWIKH-2
  Electrode
Color Code
Filling Solution
Min. Slope/Decade
Concentration Range
Selectivity Coeffiecients (-log)
TIPCA 
Calcium Green 0.1M CaCl2 28mV 0.1 - 10-6.75M Na+ 5.5, K5.4, Mg++ 4.9
TIPH 
Hydrogen Orange 1M Citric acid, 0.01M NaCl, pH 5.6 54mV pH 5.0-12 Na+ 10.4, K9.8, Ca++ 11.1
TIPK 
Potassium Yellow 0.1M KCl 54mV 0.1 - 10-4.5M Na+ 4.0, Ca++ 3.9, Mg++3.0
TIPTPP 
TPP+ Purple 10mM TPP+ 54mV 0.001 - 10-4M K6.0

G.G. Kramarenko, S.G. Hummel, S.M. Martin, G. R. Buettner "Ascorbate Reacts with Singlet Oxygen to Produce Hydrogen Peroxide" Photochemistry and Photobiology 86. 2006: 1634-1637