Ion Selective Electrode - Calcium

$506.00
Order code
KWIKCAL-2

Accurately measure calcium

  • Fast, accurate, economical
  • Superior, stable PVC membrane
  • Fast response
  • 2mm diameter tips
  • Interchangeable tip holder
  • Each kit includes 3 electrode tips and MicroFil filling syringe

Benefits

  • Inexpensive
  • Use to measure various ions in biological media

Applications

  • Detection of ions in vivo or in vitro for biological applications

These highly stable electrodes ac­cu­rate­ly measure cal­ci­um, po­tas­si­um, hydrogen and TPP (Tetraphenylphosphonium) ion activity. Tips consist of 2 mm di­am­e­ter plas­tic tubes sealed at one end with an ion-sen­si­tive mem­brane. After filling with elec­tro­lyte so­lu­tion, you can in­sert the tube into the hold­er and con­nect it to a pH meter. Tips and hold­ers are in­ter­change­able, so one tip may be re­placed with an­oth­er sensitive to a dif­fer­ent ion. Replac­ing a tip takes less than a minute. Elec­trode tips nor­mal­ly last sev­er­al months, when stored proper­ly in sa­line so­lu­tion. When re­place­ment is neces­sary, only the tip needs be re­placed.

Kwik-Tip electrodes are available separately and as kits. Each “KWIK” Elec­trode Holder kit includes a reus­able hold­er and three re­mov­able tips. In addition to a 4-foot BNC ca­ble and an electrolyte filling syringe; “TIP” Elec­trode Kits con­tain three elec­trode tips for a specific ion. A separate ref­er­ence electrode, such as WPI’s Dri-Ref™, is also required.

If your pH meter requires a US Standard connector, you will also need Part 3508 (BNC-to-US pH Standard adapter).

  Electrode
Color Code
Filling Solution
Min. Slope/Decade
Concentration Range
Selectivity Coeffiecients (-log)
TIPCA
Calcium Green 0.1M CaCl2 28mV 0.1 - 10-6.75M Na+ 5.5, K+ 5.4, Mg++ 4.9
TIPH
Hydrogen Orange 1M Citric acid, 0.01M NaCl, pH 5.6 54mV pH 5.0-12 Na+ 10.4, K+ 9.8, Ca++ 11.1
TIPK
Potassium Yellow 0.1M KCl 54mV 0.1 - 10-4.5M Na+ 4.0, Ca++ 3.9, Mg++3.0
TIPTPP
TPP+ Purple 10mM TPP+ 54mV 0.001 - 10-4M K+ 6.0

 

 

A.S. Murphy, W.R. Eisinger, J.E. Shaff, L.V. Kochian, L. Taiz "Early Copper-Induced Leakage of K+ from Arabidopsis Seedlings Is Mediated by Ion Channels and Coupled to Citrate Efflux1" Plant Physiology 121. 1999: 1375-1385

More Choices:
  1. Micro Dri-Ref Reference Electrode
    Micro Dri-Ref Reference Electrode
    DRIREF-450
    $217.00
  2. Dri-Ref Reference Electrode, 4.7 mm
    Dri-Ref Reference Electrode, 4.7 mm
    DRIREF-5
    $130.00
  3. Dri-Ref Reference Electrode, 4.7 mm (short)
    Dri-Ref Reference Electrode, 4.7 mm (short)
    DRIREF-5SH
    $130.00
  4. Dri-Ref Reference Electrode with Luer Tip
    Dri-Ref Reference Electrode with Luer Tip
    DRIREF-L
    $217.00
  5. Flexible Dri-Ref Reference Electrode
    Flexible Dri-Ref Reference Electrode
    FLEXREF
    $130.00
  6. Electrode Holder for KWIK-Tips
    Electrode Holder for KWIK-Tips
    KWIK-2
    $164.00
  7. Super Dri-Ref Reference Electrode
    Super Dri-Ref Reference Electrode
    SDR2
    $176.00
  8. Calcium Electrode Tips, Replacement
    Calcium Electrode Tips, Replacement
    TIPCA
    $389.00
  9. Dri-Ref Reference Electrode, Short
    Dri-Ref Reference Electrode, Short
    DRIREF-2SH
    $130.00
  10. Hydrogen Electrode Tip, Replacement
    Hydrogen Electrode Tip, Replacement
    TIPH
    $243.00
  11. Dri-Ref Reference Electrode, 2 mm
    Dri-Ref Reference Electrode, 2 mm
    DRIREF-2
    $130.00
  12. TPP Electrode Tips, Replacement
    TPP Electrode Tips, Replacement
    TIPTPP
    $179.00

This product requires the use of a reference electrode, like the DriRef-2. For a complete list of the DriRef electrodes, refer to the Accessories tab.

kwiktipapplication.png

Frequently Purchased
©Copyright 2020. World Precision Instruments. All rights reserved.

Apply for Tax Exempt Status
WPI collects tax in AL, AZ, CA, CO, CT, DC, FL, GA, IL, IN, MA, ME, MD, MI, MN, MO, NC, NV, NJ, NY, OH, OK, PA, SC, TN, TX, VA, VT, WA and WI