Nanoliter 2000 Injector 120 V

Order # B203XVY

Nanoliter 2000 Injector 120 V
View Full-Size Image


 
Ask a question about this product

  • Microprocessor-controlled injector
  • Uses direct piston displacement
  • Filling and injection speeds: 23nL/sec and 46 nL/sec
  • Optional controller or footswitch



Click here to visit the online store. Not all products are available in the store.



Injection volumes

WPI™s microprocessor-controlled Nanoliter 2000 uses direct piston displacement. By either pushing the injection button on the control box or pressing on the optional footswitch, a calibrated volume will be smoothly injected. The process is quiet and vibration free. Capillary filling and injection speeds are 23 nL/sec and 46 nL/sec (emptying speeds are 92 nL/sec and 230 nL/sec). Maximum fluid ejection is 5 µL. Each unit comes with sufficient glass to pull at least 300 tips. Glass is 1.14 mm O.D. (nominal) and 0.5mm I.D. By setting the DIP switch, the injection volume can be changed from 2.3 to 69.0 nL in 16 steps. Up to 100 injections may be triggered per filling. Since the volume of a normal Xenopus oocyte is about 500 nL, the instrument has the capability to inject from less than 1% to over 10% of the total volume of the oocyte in one preset step increment.

Included with pump

Included: 1 vial 3.5 in. capillaries (100); 1 vial 7 in. capillaries (100); replacement "O" rings; Allen wrench; MicroFil™ MF34G backfilling needle; and two sample pre-pulled micropipettes.

Smart controller

SYS-MICRO4, an optional microprocessor-based controller, can provide an "intelligent" and easy-to-use interface to up to four Nanoliter Injectors. Operating parameters are set with the membrane key-pad and LCD display. From the key­pad the user can set pump to infusion or withdrawal mode, enter the volume to be infused or withdrawn, and rate of delivery, as well as synchronize the starting and stopping of a combination of Injectors. User parameters can be stored in the device's "non-volatile" memory for instant recall when the unit is powered on. An optional footswitch can be plugged into a connector on the rear of the controller for "hands free" start/stop operation. An RS-232 port on the rear of the controller can be used to connect it to a computer for use with computer control programs.

Troubleshooting Tip 

INJECTION VOLUME Variable in discreet aliquot volumes
REMOTE CONTROL Yes
GLASS OD 1.14mm
GLASS ID 0.5mm
STEP 12.7µm/step
INJECTION SPEED: Slow 23nL/sec
INJECTION SPEED: Fast 46nL/sec
FILL SPEED: Slow 23nL/sec
FILL SPEED: Fast 46nL/sec
EMPTY SPEED 92nL/sec
VARIABLE VOLUME RANGE 2.3 - 69.0nL
SMALLEST VOLUME 2.3nL
INJECTIONS PER FILLING, MAX. 100 injections
SHIPPING WEIGHT 3 lb. (1.1 kg)
Wilcox & Welch "Interaction between nitric oxide and oxygen radicals in regulation of tubuloglomerular feedback" Acta Physiologica Scandinavica 168. 2000: 119-124
To place an order for this product, please contact the appropriate WPI office or distributor.

Customers from North America can order direct from our corporate office:
World Precision Instruments
175 Sarasota Center Boulevard
Sarasota, FL 34240-9258
  • Phone or Fax
    Toll-free: 866-606-1974 Tel: 941-371-1003 Fax: 941-377-5428
  • Our Customer Service Representatives are available 8am - 6pm EST.
  • Online Store
    Many of our products are available for purchase through our online store. At this time we can only accept orders from the U.S. through the online store.
  • Want instant pricing? Order a free catalog here
International customers, please see our office and distributor contact information list.
13142
Footswitch for Nanoliter 2000
15867 Footswitch for Micro4 Controller
300033
Adapter for Micro4
4878
Replacement 3.5-in. glass capillaries (300)
4879
Replacement 7-in. glass capillaries (300)
5340 Spare Parts Kit (includes MicroFil MF34G, displacement piston, five O-ring sets
500299 Pistons, 5-pack
500778 
Replacement Nanoliter Injector Universal Adapter
502859
Flared O-Ring Kit
503066
Flared Glass, 100 piece.
SYS-MICRO4
Micro4 Controller, 4-channel
TIP10XV119
Micropipettes for Nanoliter Injector (10)
MF34G-5 MicroFill, 34g (pkg. of 5)

The following images show various setups using the Nanoliter 2000. Keep in mind that parts are interchangeable. For example:

  • M10 or the M9 magnetic base could be used.
  • PZMTIV microscope could be used instead of the PZMIII.
  • M330l or the KITE micromanipulators can be used, and these micromanipulators can be placed on either side. (Keep in mind, though, If you wanted to use a KITE on the right side of the setup below, you would order a KITE-R (right hand), or if you want an M3301 on the left side, you would order an M3301-L.)
  • 5479 or 5052 magnetic bases are virtually interchangeable.
  • One or two Nanoliters, one or two UMPIII systems, or one Nanoliter and one UMPIII may be used, as desired.
ONE NANOLITER/ONE UMP3-1

ONE NANOLITER

ONE NANOLITER/M3301

  ONE NANOLITER/KITE

 

more categories


Cuvettes & Holders

Fiber optic cuvette holders and quartz cuvettes for spectrophotometry and fluorometry.
• Adjustable cuvette holder (2–100mm), ABS/FL cuvette holder, fiber optic holders for glass fiber filters (GFF)
• Standard rectangular, semi-micro, continuous flow, micro, fluorescence and cylindrical cuvettes
Choosing a Cuvette: Optical Glass or Quartz



Detectors

Fiber Optic Detectors for Absorbance, Fluorescence, Transmittance and Reflectance spectroscopy. LEDSpec is a stand alone LED-based bio-photometric detection system targeted at flow analysis and single-scan applications. Tidas I is a photodiode array based spectrometer for low noise and drift. SpectraUSB series are miniature CCD array spectrometer modules for generic UV/VIS spectroscopy.



Detection Systems

WPI's modular spectroscopy components can be assembled into a large variety of sampling systems. Some applications include:
• DNA/RNA/Protein analysis
• Oceanographic nutrient analysis
• Ocean color research
• Process control
• Pharmaceutical research



Dipping Probes

Fiber optic dipping probes for UV/VIS/NIR spectroscopic analysis. Easy, quick and accurate spectroscopic sampling of microliter volumes.



Flow Cells

Fiber optic flow cells for UV/VIS/NIR spectroscopy. WPI's Liquid Waveguide Capillary Cell technology allows path lengths between 2 and 500 cm and at volumes of 5 to 1500 microliter. Applications include fluid injection analysis, HPLC and process control. For more information or help choosing an appropriate flow cell, see the LWCC Details page.



Light Sources

Fiber optic light sources for UV, VIS and NIR absorbance, fluorescence and reflectance applications. These deuterium, tungsten and LED based light sources are optimized for low noise and low drift.



Optical Fibers

Fused silica fibers with core diameters from 50 to 1000 micrometers. Solarization resistant fibers are available for deep UV applications. Bifurcated fiber optic assemblies can be used to split or combine similar light intensities. Polymer based fibers are available as a highly flexible, stable and inexpensive alternative.



Spectroscopy Accessories

Fiber Optic Inline Filter holders for interference filters, SMA bulkhead fittings, SMA and ST collimators, Fiber Optic Adapter for Thermo's UV1000 and UV2000 HPLC detectors, Sampling accessories for LWCCs, Dipping Probes, etc.



Specialty Systems

Highly sensitive, benchtop systems for Electron Spin Resonance/Electron Paramagnetic Resonance and Surface Plasmon Resonance can be found here.



Last Updated: Saturday, 11 February 2012 14:19


TOLL FREE: 866.606.1974