Quote Cart

Your Cart is currently empty.

Products Menu

like us on facebook New stuff, articles, promos

Tech Support and Returns

PDFPrintE-mail

One-Channel Free Radical Analyzer

Order # TBR1025

One-Channel Free Radical Analyzer
View Full-Size Image


 
Ask a question about this product

  • Real-time detection using electrochemical microsensors
  • Integrated system - includes sensors and start-up kit
  • Measure up to 4 species
  • Wide dynamic range for detection



Click here to visit the online store. Not all products are available in the store.



Click here to view the current Data Sheet.

Details

Current measurement range from 300 fA to 10 µA (four ranges) permits wide dynamic range for detection * Wide bandwidth allows recording of fast events * Measure nitric oxide from < 0.3 nM to 100 µM * Measure hydrogen peroxide < 10 nM to 100 mM * Measure hydrogen sulfide * Measure glucose * Measure oxygen from 0.1% to 100% * Isolated architecture allows Lab-Trax interface to simultaneously measure free radical and independent analog data (i.e., ECG, BP, etc.) data on any channel

Real-time detection

Real-time detection and measurement of a variety of redox-reactive species is fast and easy using the electrochemical (amperometric) detection principle employed in the new TBR4100. This optically isolated single-channel free radical analyzer has ultra low noise and independently operated channels.

Measure multiple species

TBR1025 is designed for use with WPI’s wide range of nitric oxide, hydrogen peroxide, hydrogen sulfide and oxygen sensors. Simply plug a sensor into the input channel on the front panel and select the current range. Poise voltage can be selected from a range of values tuned for optimal response from WPI sensors.

Data acquisition

The TBR1025 analyzer utilizes PC-based data acquisition via our Lab-Trax interface; data traces are displayed and recorded in real-time. The LabScribe software comes pre-configured for single or multiple electrode recording; filters, gains, and smoothing are all set for optimal results. Data can be viewed making adjustments to smoothing and filter settings without affecting the original stored raw data. Electrode calibration from multiple concentration readings can be input into the software's Multipoint Calibration utility quickly provides a plot and slope calculation for electrode sensitivity determination.

DataTrax, LabScribe, Data Recorder, Lab Trax, Lab-Trax, Data-Trax, Data Acquisition, Data Logger

Power 100 ~ 240 VAC, 50-60 Hz, <15 W
Operating Temperature (ambient) 0 - 50°C (32 - 122°F)
Operating Humidity (ambient) 15 - 70% RH non-condensing
Warm up Time <5 minutes
Dimensions 135 X 419 X 217 mm (5.25" X 16.5" X 8.16")
Weight 1.35 kg (3 lb)
Display Functions 18 mm (0.7") LCD readout, 4.5 digit Polarization Voltage (mV) Current input (nA, µA)
Controls Power (on/off) Current Input Range Polarization Voltage
Analog Output Range +/- 10 V (continuous)
Analog Output Impedance 10 kohm
Channel to Channel Isolation >10 Gohm
Channel to Output Isolation >10 Gohm
Power Supply to AC Line Isolation >100 Mohm
Analog Output Drift <10 pA/h
Temperature Input: Number of Channels 1
Temperature Input: Sensing Element Platinum RTD, 1000 Ohm
Temperature Input: Range 0-100°C
Temperature Input: Accuracy +/- 1°C
Temperature Input: Resolution 0.1°C
Temperature Input: Analog Output 31.25 mV/°C (continuous)
Amperometric Input: Number of Amperometric Channels 1
Amperometric Input: Signal Bandwidth 0-3 Hz
Amperometric Input: Polarization Voltage (selectable via rotary switch) Nitric Oxide 865 mV
Amperometric Input: Polarization Voltage (selectable via rotary switch) Hydrogen Sulfide 150 mV
Amperometric Input: Polarization Voltage (selectable via rotary switch) Hydrogen Peroxide 450 mV
Amperometric Input: Polarization Voltage (selectable via rotary switch) Glucose 600 mV
Amperometric Input: Polarization Voltage (selectable via rotary switch) Oxygen 700 mV
Amperometric Input: Polarization Voltage (selectable via rotary switch) ADJ (user adjustable) +/- 2500 mV
Polarization Voltage Accuracy +/- 5 mV
Polarization Voltage Display Resolution +/- 1mV
Current measurement Performance: Range +/- 10 Na, +/- 100 nA, +/- 1 µA, +/- 10 µA
Current measurement Performance: Analog Output 1 mV / 1 pA, 1 mV / 10pA, 1 mV / 100pA, 1 mV / 1µA
Current measurement Performance: Noise @ 3Hz * < 1 pA, < 7 pA, < 70 pA, < 700 pA
Current measurement Performance: Noise @ 0.3 Hz * < 0.3 pA, < 3 pA, < 30 pA, < 300 pA
Notes: *Instrument performance is measured as the (max-min) over 20 seconds period with open input. Typical values are given at 3 Hz and 0.3 Hz bandwidth.
Typical sensor performance with TBR4100: ISO-NOPF100 noise 0.2 nM NO (<2 pA)**
Notes: **Sensor noise is measured as the (max-min) over a 20 seconds period with the sensor immersed in 0.1 M CuCl2 solution.
There are no references for this product.
To place an order for this product, please contact the appropriate WPI office or distributor.

Customers from North America can order direct from our corporate office:
World Precision Instruments
175 Sarasota Center Boulevard
Sarasota, FL 34240-9258
  • Phone or Fax
    Toll-free: 866-606-1974 Tel: 941-371-1003 Fax: 941-377-5428
  • Our Customer Service Representatives are available 8am - 6pm EST.
  • Online Store
    Many of our products are available for purchase through our online store. At this time we can only accept orders from the U.S. through the online store.
  • Want instant pricing? Order a free catalog here
International customers, please see our office and distributor contact information list.
No application notes are available for this product at this time.

Recently Viewed Products

Last Updated: Friday, 10 February 2012 06:24


TOLL FREE: 866.606.1974