  • Simultaneously measures electric potential and pressure
  • Preset internal microelectrode pressure
  • Air-filled system-no debubbling
  • Reference Electrode required–please contact WPI



Click here to visit the online store. Not all products are available in the store.



Details

Model 900A is designed to measure hydrostatic pressure in small vessels and cells. Pressure ranges of -200 to +400 mm Hg can be measured with stability and accuracy. The system’s sensing element is an electrolyte-filled glass microelectrode with a tip diameter range of 2 to 5 microns. Pressures of electrolyte solutions are measured by maintaining a salt concentration gradient at the tip of the sensing electrode in dynamic equilibrium by applying an equal air pressure inside the microelectrode. The pressure reading appears on the front panel display and via the BNC recorder output. Because the piezoelectric pressure controller uses external pressure and vacuum sources, pressures lower than -200 to greater than +400 mm Hg can be quickly and accurately measured at the microelectrode tip.

Open pressure chamber

The open pressure chamber is almost immune to vibrations and movements and, unless they are extremely large, the open system is unaffected by leaks. The pressure controller is contained in a small, lightweight enclosure that can easily be mounted near the micropipette to help reduce dead space. It includes an amplifier, a piezoelectric valve and a pressure transducer. The user supplies fluid-filled microelectrodes, +500 mm Hg pressure source and a -300 mm Hg vacuum source.

Electric potential

Measuring electric potential and pressure simultaneously lets you use potential recording as an additional cue for locating the electrode where visibility is limited, or correlate pressure and potential when this is meaningful. The unique “Set Pressure” mode lets you preset the internal pressure of the microelectrode - select a positive pressure for flushing the tip, or a negative pressure for pulling solution into the tip. By disconnecting the microelectrode holder and attaching the tubing to a manometer, you can check the calibration against a standard.

Built-in alarm

A built-in alarm sounds to indicate maximum pressure. The alarm also sounds when the tip is blocked or electrical continuity is broken (e.g., the microelectrode comes out of the solution, too little filling solution to cover the Ag/AgCl pellet, disconnected ground reference, etc.).

Piezoelectric pressure controller

The piezoelectric pressure controller regulates internal pipette pressure by controlling air flow into and out of a small pressure chamber. A vacuum source is connected on the outlet side of the chamber, and a piezoelectric valve meters air entering the pressurized chamber. The residual volume of the pressure chamber includes the micropipette, the connecting tubing and the pressure transducer on the outlet side of the piezoelectric valve. The 900A accurately controls and adjusts the pressure in the chamber to match pressures applied externally to the microelectrode tip. The response time of the piezoelectric valve is 0.5?ms from fully closed to fully open. Overall system response time depends largely on the amount of residual volume in the tubing. When this volume is small, the system responds very rapidly (typically 10 milliseconds).

Minimize dead space

The lightweight pressure controller pod may be mounted close to the microelectrode using small-bore tubing, to minimize system dead space.

Note

Microelectrode holders MEH6RF and MEH6SF for 1.0?mm O.D. capillary glass included. (1.2, 1.5 and 2.0?mm also available - please specify when or­dering.)

There are no specifications for this product.
R.R. Myers, B.L. Rydevik, H.M. Heckman, H.C. Powell "Proximodistal Gradient in Endoneurial Fluid Pressure" Experimental Neurology 102. 1988: 368-370
To place an order for this product, please contact the appropriate WPI office or distributor.

Customers from North America can order direct from our corporate office:
World Precision Instruments
175 Sarasota Center Boulevard
Sarasota, FL 34240-9258
  • Phone or Fax
    Toll-free: 866-606-1974 Tel: 941-371-1003 Fax: 941-377-5428
  • Our Customer Service Representatives are available 8am - 6pm EST.
  • Online Store
    Many of our products are available for purchase through our online store. At this time we can only accept orders from the U.S. through the online store.
  • Want instant pricing? Order a free catalog here
International customers, please see our office and distributor contact information list.
900AP Replacement Probe
CAL900A
Pressure Calibration Chamber
3491 Probe Extension Cable
2933 Rack mount Kit
5332 Replacement Liquid Trap
MEH6RF Micropipette Holder
MEH6SF Micropipette Holder
TIPTW900A
Prepulled Micropipette for 900A (1mm thin wall, 2µTip)
900APP Replacement Pressure Pod
SYS-PM015D Pressure Manometer (15psi)
No application notes are available for this product at this time.
Last Updated: Friday, 10 February 2012 06:51


TOLL FREE: 866.606.1974