Fiber Optic Oxygen Meter for Microsensors

Order # OXY-MICRO-AOT

Fiber Optic Oxygen Meter for Microsensors
View Full-Size Image


 
Ask a question about this product

  • Detection based on luminescence lifetime
  • Excellent long-term stability
  • Fast response time (<0.5 sec for MicroTip sensors)
  • Measurement is feasible in dry gas
  • Immune to electrical and magnetic interferen


Click here to visit the online store. Not all products are available in the store.



Click here to view the current Data Sheet.   

Features

The OxyMicro is designed for biological research applications including implanting into tissues, cell cultures, profiling of biofilms and sediment related bioassays. The measurement principle of the sensor system is based on the detection of oxygen concentration as a function of luminescence lifetime either in dissolved or gaseous phase environments. The fiber optic oxygen meter is compact and easy to transport. It was designed for in/outdoor use and can be connected to a PC via a RS232 interface. Data can be visualized, analyzed and stored with the supplied software. A full range of sensors covering most biomedical applications are available.

Measurement Principle

Conventional fiber-optic oxygen sensor systems based on intensity measurements are limited in their accuracy by light source stability and ambient light fluctuations. Using a luminescence lifetime detection, measurements are not affected by light source stability, intensity fluctuations caused by fiber bending or changes of the optical properties of the sample (turbidity, refractive index, coloration, etc.). These advantages make WPI™s OxyMini and OxyMicro the most advanced and reliable fiber-optic oxygen system available.

Calibration

The sensors can be calibrated by a simple two point calibration, 100% air-saturation and 0% air saturation.

Applications

The OxyMicro is a single channel fiber optic oxygen meter for WPI™s fiber optic oxygen microsensors. Applications include:

  • Oxygen profiles of marine sediment, soils, or tissue
  • Implantation into living tissue (e.g., heart or muscle tissue)
  • Control of cell culture media in Biotechnology.
There are no specifications for this product.
There are no references for this product.
To place an order for this product, please contact the appropriate WPI office or distributor.

Customers from North America can order direct from our corporate office:
World Precision Instruments
175 Sarasota Center Boulevard
Sarasota, FL 34240-9258
  • Phone or Fax
    Toll-free: 866-606-1974 Tel: 941-371-1003 Fax: 941-377-5428
  • Our Customer Service Representatives are available 8am - 6pm EST.
  • Online Store
    Many of our products are available for purchase through our online store. At this time we can only accept orders from the U.S. through the online store.
  • Want instant pricing? Order a free catalog here
International customers, please see our office and distributor contact information list.
501656
Fiber Optic Oxygen sensor
501657
Flow-through Housed Oxygen Micro sensors
501658
Implanable Oxygen Microsensor
No application notes are available for this product at this time.
more categories


Cuvettes & Holders

Fiber optic cuvette holders and quartz cuvettes for spectrophotometry and fluorometry.
• Adjustable cuvette holder (2–100mm), ABS/FL cuvette holder, fiber optic holders for glass fiber filters (GFF)
• Standard rectangular, semi-micro, continuous flow, micro, fluorescence and cylindrical cuvettes
Choosing a Cuvette: Optical Glass or Quartz



Detectors

Fiber Optic Detectors for Absorbance, Fluorescence, Transmittance and Reflectance spectroscopy. LEDSpec is a stand alone LED-based bio-photometric detection system targeted at flow analysis and single-scan applications. Tidas I is a photodiode array based spectrometer for low noise and drift. SpectraUSB series are miniature CCD array spectrometer modules for generic UV/VIS spectroscopy.



Detection Systems

WPI's modular spectroscopy components can be assembled into a large variety of sampling systems. Some applications include:
• DNA/RNA/Protein analysis
• Oceanographic nutrient analysis
• Ocean color research
• Process control
• Pharmaceutical research



Dipping Probes

Fiber optic dipping probes for UV/VIS/NIR spectroscopic analysis. Easy, quick and accurate spectroscopic sampling of microliter volumes.



Flow Cells

Fiber optic flow cells for UV/VIS/NIR spectroscopy. WPI's Liquid Waveguide Capillary Cell technology allows path lengths between 2 and 500 cm and at volumes of 5 to 1500 microliter. Applications include fluid injection analysis, HPLC and process control. For more information or help choosing an appropriate flow cell, see the LWCC Details page.



Light Sources

Fiber optic light sources for UV, VIS and NIR absorbance, fluorescence and reflectance applications. These deuterium, tungsten and LED based light sources are optimized for low noise and low drift.



Optical Fibers

Fused silica fibers with core diameters from 50 to 1000 micrometers. Solarization resistant fibers are available for deep UV applications. Bifurcated fiber optic assemblies can be used to split or combine similar light intensities. Polymer based fibers are available as a highly flexible, stable and inexpensive alternative.



Spectroscopy Accessories

Fiber Optic Inline Filter holders for interference filters, SMA bulkhead fittings, SMA and ST collimators, Fiber Optic Adapter for Thermo's UV1000 and UV2000 HPLC detectors, Sampling accessories for LWCCs, Dipping Probes, etc.



Specialty Systems

Highly sensitive, benchtop systems for Electron Spin Resonance/Electron Paramagnetic Resonance and Surface Plasmon Resonance can be found here.



Last Updated: Saturday, 11 February 2012 14:21


TOLL FREE: 866.606.1974