Click here to view the current Data Sheet.
The Small Animal Ventilator, suitable for a mouse or guinea pig, operates as either a volume or pressure-cycled ventilator, meaning that it dispenses a designated volume of air with each breath or it ventilates until a designated lung pressure is reached. Pressure-cycled ventilation prevents hyper-inflation of small animal lungs. When the ventilator operates in Volume mode, it dispenses a known airflow into the lungs for a set inspiratory time to generate the desired tidal volumes. The three controls – respiratory rate, inspiratory time and flow rate – allow for accuracy and extraordinary flexibility over a wide range of volumes, breaths-per-minute and I/E ratios. When the ventilator operates in Pressure mode, a built-in solid-state transducer monitors airway pressure. Simply set the desired end-inspiratory pressure. During inspiration, airflow is introduced into the lungs until this pressure is reached, at which point inspiration is terminated. This mode is especially useful for tiny animals, where hyperinflation of the lungs is a danger. An output voltage corresponding to airway pressure is provided for external monitoring or recording.
The SAR-830/AP ventilator comes with an internal air pump, but it can also connect with an external pressurized air or gas source for operation. This can be any suitable breathing gas within the required pressure range or the output from an anesthesia machine. It is compatible with inhalation anesthetics and oxygen. This unit may be expanded to ventilate larger animals or multiple small animals simultaneously by adding external valve assemblies. A metered flow source is required for each external valve assembly. These valves are available for animals ranging in size from mice to large dogs.
| Respiratory rate range
|
5-200 breaths/min
|
| Tidal Volume range *
|
0.2 - 35ml
|
| Inspiration time range
|
0-5.00 seconds
|
| Inspiratory flow rate range
|
0-1000 ml/min
|
| Pressure control range
|
0-50.0 cmH2O
|
| Analog rate output voltage
|
10mV/breath/min
|
| Analog pressure output voltage
|
50mV/cmH2O
|
| Logic Sync Out voltage
|
5V (TTL)
|
| Power requirements
|
120/240VAC, selectable
|
| Input pressure range **
|
3-20 psi
|
| Dimensions
|
9Wx5.5Hx9D in(23x14x23 cm)
|
*Using internal valves. External valve assemblies available for larger animals.
** No pressure source required for model SAR
To place an order for this product, please contact the appropriate WPI office or distributor.
Customers from North America can order direct from our corporate office:
World Precision Instruments
175 Sarasota Center Boulevard
Sarasota, FL 34240-9258
- Phone or Fax
Toll-free: 866-606-1974 Tel: 941-371-1003 Fax: 941-377-5428
Our Customer Service Representatives are available 8am - 6pm EST.
- Online Store
Many of our products are available for purchase through our online store.
At this time we can only accept orders from the U.S. through the online store.
-
Want instant pricing? Order a free catalog here
International customers, please see our
office and distributor contact information list.