- Flexible Teflon microprobes are used for implantation in tissue, in spectrophotometer cuvettes, rectally in neonatal mice, in water baths, PCR thermal cyclers, etc.
- Animal rectal temperatures during surgical procedures and pyrogen testing.
- Skin temperature measurement during exercise physiology studies.
When precise temperature measurements are required, WPI can provide you with a very accurate monitor and thermocouple microprobes. WPI monitors have both resolution and accuracy of 0.1°C in the 0-50°C range and are traceable to NIST standards, whereas, other competitive electronic thermometers have an accuracy that is usually to 0.5°C or worse. Furthermore, all our type T clinical probes are guaranteed accurate to 0.1°C, due to our stringent wire standards. These are five times more accurate than competitive probes made with regular “Special Limits” wire.


NEEDLE MICROPROBES
Fast-response needle probes for instant readings in tissue, semisolids, liquids, very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen.
|
PROBE TYPE
|
SIZE
|
STYLE
|
TIME CONSTANT
|
ISOLATED
|
MAX TEMP
|
LEAD LENGTH
|
DESCRIPTION
|
MT-29/1

|
29 ga/1cm
|
A
|
0.125 sec
|
No
|
200°C
|
5 ft
|
29 gauge approximately 0.013-in
|
MT-29/2
 |
29 ga/2cm
|
A
|
0.125 sec
|
No
|
200°C
|
5 ft
|
-
|
MT-29/3
 |
29 ga/3cm
|
A
|
0.125 sec
|
No
|
200°C
|
5 ft
|
-
|
MT-29/5
 |
29 ga/5cm
|
A
|
0.125 sec
|
No
|
200°C
|
5 ft
|
-
|
MT-26/2

|
26 ga/2cm
|
A
|
0.1 sec
|
No
|
200°C
|
5 ft
|
26 gauge approximately 0.018-in
|
MT-26/4
 |
26 ga/4cm
|
A
|
0.1 sec
|
No
|
200°C
|
5 ft
|
-
|
MT-26/6

|
26 ga/6cm
|
A
|
0.1 sec
|
No
|
200°C
|
5 ft
|
-
|
MT-23/3
 |
23 ga/3cm
|
A
|
0.15 sec
|
No
|
200°C
|
5 ft
|
23 gauge approximately 0.125-in
|
MT-23/5
 |
23 ga/5cm
|
A
|
0.15 sec
|
No
|
200°C
|
5 ft
|
-
|
MT-23/8

|
23 ga/8cm
|
A
|
0.15 sec
|
No
|
200°C
|
5 ft
|
-
|
MT-4
 |
29 ga/1cm
|
A
|
0.025 sec
|
No
|
200°C
|
5 ft
|
Similar to MT-29/1 but has a blunt tip. Good for instant skin and surface temperatures, liquids
|
MT-D

|
-
|
C
|
0.025 sec
|
No
|
200°C
|
5 ft
|
Fast response surface probe (stainless steel for locating inflammation, arteries, etc. Also for dental use.
|
MT-29/1B
 |
29 ga/1cm
|
B
|
0.015 sec
|
No
|
150°C
|
5 ft
|
Insect Probe. Similar to MT-29/1 except sensor is welded into tip for maximum heat transfer. Other sizes made to special order.
|
FLEXIBLE IMPLANTABLE PROBES
Designed for high accuracy on extremely small specimens such as insects, seeds, etc. Maximum insertion depth 1/8". Totally sheathed in chemical resistant Teflon.
|
PROBE TYPE
|
SENSOR LEAD DIAMETER
|
STYLE
|
TIME CONSTANT
|
ISOLATED
|
MAX TEMP
|
LEAD LENGTH
|
DESCRIPTION
|
IT-14

|
0.050" dia
|
D
|
0.3 sec
|
Yes
|
150°C
|
3 ft
|
-
|
IT-18
|
0.025" dia
|
D
|
0.1 sec
|
Yes
|
150°C
|
3 ft
|
-
|
IT-18EXLONG
  |
0.025” dia.
|
D
|
-
|
Yes
|
150°C
|
5 ft
|
|
IT-21

|
0.016" dia
|
D
|
0.08 sec
|
Yes
|
150°C
|
1 ft
|
|
IT-23

|
0.009" dia
|
E
|
0.005 sec
|
Yes
|
150°C
|
3 ft
|
For ultra fast measurements and for use on micro-size specimens. Tissue implantable with 239a. Needle (supplied). Rather fragile. Teflon coated.
|
IT-1E
 |
0.025" dia
|
F
|
0.005 sec
|
Yes
|
150°C
|
3 ft
|
As IT-18 sensor except bead exposed. Combines ultra- fast reponse of IT-23 with sheath strength of IT-18.
|
|
RECTAL PROBES
|
|
PROBE TYPE
|
SENSOR LEAD DIAMETER
|
STYLE
|
TIME CONSTANT
|
ISOLATED
|
MAX TEMP
|
LEAD LENGTH
|
DESCRIPTION
|
RET-2

|
-
|
G
|
0.8 sec
|
No
|
125°C
|
5 ft
|
Rectal probe for rats typically for fast intermittent measurements. Smooth ball tip (0.125-in. dia.) with 1" long (0.59-in. dia) stainless steel shaft.
|
RET-3

|
-
|
G
|
0.5 sec
|
No
|
125°C
|
5 ft
|
Rectal probe for mice similar to RET-2 except tip diam. 0.063-in. and shaft 3/4-in. long (0.028-in. diam.)
|
GENERAL PURPOSE
|
PROBE TYPE
|
SENSOR LEAD DIAMETER
|
STYLE
|
TIME CONSTANT
|
ISOLATED
|
MAX TEMP
|
LEAD LENGTH
|
DESCRIPTION
|
HT-1

|
|
H
|
0.5 sec
|
No
|
400°C
|
5 ft
|
“Workhorse” probe for liquids, gases, semi-solids. Plastic handle with straight stainless steel shaft. Not good for surface temperatures.
|
HT-2

|
|
H
|
0.5 sec
|
No
|
400°C
|
5 ft
|
Like HT-1 except shaft length is 9-in.
|
BT-1
  |
|
I
|
0.15 sec
|
No
|
240°C
|
5 ft
|
Plastic handle with welded stainless steel, immersible shaft used for surface temperatures of solids, liquids, gases and semisolids. Tip is 0.02-in. diam., at right angle to probe to facilitate surface measurement.
|
|